Brivis Error Code 50, Ignition Lockout Explained
Brivis error code 50 appears when the ducted gas heater has tried to light four times in a row and failed every time.
To stay safe, it locks itself out and waits for someone to reset it. A reset clears the code, yet the heater will usually lock out again unless the reason behind the failed starts is fixed. This page explains what the lockout means, how to reset correctly and how to find the real cause.
What does Brivis error code 50 tell you?
Code 50 is a lockout code. Before it appears, the heater has already made four ignition attempts. Each attempt failed, usually with one of the ignition codes 46, 47 or 55 recorded along the way. After the fourth failure, the heater stops trying and shows code 50.
The lockout exists to stop endless restart attempts. Without it, a heater with no gas or a faulty igniter could keep cycling, wasting power and wearing parts.
How do you clear code 50?
On StarPro and Buffalo BX5 models with a Networker, press the key labelled Reset, usually Key 4. If Reset does not appear beside Key 4, press FN, then Key 1, then Key 4. The heater then tries to start again.
When the code persists, turn the Networker off, wait two minutes and turn it on. As a last step, switch off the heater at its power point for about a minute and then switch it back on. Our reset guide covers these steps and the Classic model process.
Why does code 50 often come back?
The manual is clear on this point. The heater will probably lock out again unless someone resolves the causes behind codes 46, 47 and 55. In other words, the reset only gives the heater another four attempts. If the gas is still off or the igniter is still faulty, those attempts will fail too.
So before resetting, work through the gas checks below.
Which checks should you make before resetting?
These checks address the most common causes.
- Make sure gas is on at the meter.
- Check that someone has not closed the gas tap beside the heater.
- Test another gas appliance, such as the cooktop or water heater.
- For LPG, check the cylinder level and turn its valve fully on.
- Check with your gas supplier about outages in your area.
If all of these are fine and the heater still locks out, it needs a service. Our ignition codes page explains the internal causes.
What internal faults lead to code 50?
The most common internal causes are dirty burners, a worn or cracked igniter, a dirty or misplaced flame sensor, low gas pressure at the heater, a faulty gas valve and a failing control board. A partly blocked flue can also interrupt ignition, because the heater checks flue airflow before lighting.
Each of these needs a licensed gas fitter. Please do not remove panels or touch gas parts.
Is code 50 dangerous?
The lockout itself is a safety feature, so it is protecting you. However, the underlying cause could involve gas, so treat it seriously. If you smell gas, do not reset. Turn the gas off at the meter, open doors and windows, leave the area and call your gas supplier or emergency services. Our gas smell guide has more detail.
How many times should you reset?
Reset once after checking the gas supply. If the heater locks out again, stop and call a technician. Repeated resets do not fix anything and can add wear to the igniter and gas valve. They also make it harder to see the pattern of faults.
Why does code 50 appear more in early winter?
At the start of the heating season, heaters that have sat idle all summer often have dusty burners, spider webs in burner ports and sensors coated with grime. Those problems cause failed ignition, and four failures lead to a lockout. A pre winter service avoids most of these first night lockouts.
Do LPG homes see more code 50 lockouts?
LPG homes can see more lockouts during cold spells. As a cylinder runs low, its pressure drops, and very cold weather lowers it further. The heater may then struggle to light. Keeping a full spare cylinder connected through a changeover valve, or arranging regular deliveries, helps prevent this.
What does the ignition sequence look like from outside?
When the controller calls for heat, you may hear a small fan start inside the heater. That is the combustion fan, which clears the flue. A few seconds later, you may hear the click of the igniter and the soft rush of burners lighting. About a minute after that, the main fan starts and warm air begins to reach the outlets.
When ignition fails, you hear the combustion fan and the igniter, but no burner noise follows. After a pause, the heater tries again. On the fourth failure it goes quiet and the controller shows code 50. Knowing this pattern helps you describe what happened.
Can a power interruption cause code 50?
A brief power cut on its own usually does not cause a lockout. When power drops, safety controls shut the gas, and when power returns the heater resumes. However, if the power flickers during an ignition attempt, the sequence may fail. Several flickers in a row during a storm can stack up to four failed attempts. In that case, a single reset once power is stable may be all you need.
If the power was off for two to three hours or more, also check the Networker clock. Our power outage guide explains what to do.
What if the burners light but then go out?
Sometimes the burners light for a few seconds and then shut off. That usually means the flame sensor is not confirming the flame. A dirty sensor, a cracked sensor, a poor earth connection or low gas pressure can all cause this. Each failed confirmation counts as a failed attempt, so four in a row lead to code 50.
This pattern is common and often fixed by cleaning or replacing the sensor.
Does the flue matter for code 50?
Yes. Before lighting, the heater checks that flue gases can escape. If a bird nest, leaves or a damaged flue cap partly blocks the flue, the check may fail or the flame may be unstable. In some cases that shows as code 56, while in others it shows as ignition failures leading to code 50.
From outside, you can safely look at the flue terminal and remove loose leaves from around it. Leave the rest to a technician.
What if the heater is in the roof?
Many internal heaters sit in roof spaces. Owners should not climb into the roof to inspect the heater, as roof spaces hold hazards such as live cables, fragile ceilings and heat. The gas tap for a roof heater may sit beside the unit in the roof, which makes it harder to check. If you cannot safely reach the tap, tell us when you call.
Can a new installation show code 50?
Yes. On a newly installed heater, air in the gas line can stop the burners lighting at first. Installers usually purge the line during commissioning, but if a lockout happens soon after installation, contact the installer. The gas line size, regulator setting and gas type settings may also need checking.
How does code 50 differ from code 56?
Code 50 is about ignition. The heater could not light. Code 56 is about the pressure switch, which confirms flue airflow. Both are lockouts that need a reset, yet the causes differ. If you see both codes over a few days, mention it, because a flue or combustion fan problem can lead to either.
Can you use the heater fan without heat?
On StarPro models, you can run the fan on its own by pressing Key 1 for continuous fan, as described in our fan settings guide. That circulates air without heating, which can help spread warmth from other heaters. It will not fix the lockout, but it is useful while you wait.
What do you need to know about gas taps?
Most homes have a main gas tap at the meter and a separate appliance tap near the heater. The appliance tap is often a lever. When the lever runs in line with the pipe, the gas is usually on, and when it sits across the pipe, the gas is usually off. If you are unsure, do not force anything. Ask us or your gas fitter to check.
It is common for the heater tap to be closed after a service, a repair to a nearby appliance or work in the roof. A quick look often solves a code 50 straight away.
What if several gas appliances stopped at once?
If the cooktop, hot water and heater all stopped around the same time, the problem lies with the gas supply. Contact your gas distributor or, for LPG, your supplier. Once the supply returns, you may need to relight other appliances according to their instructions and reset the heater once.
Can a heater lock out because of old age?
Age itself does not cause lockouts, but older heaters tend to have worn igniters, coated sensors and dusty burners. They also may not have had regular servicing. In an older heater, a lockout is often the first sign that a service is overdue. After a service, many older heaters run reliably again.
If several parts are failing at once on an older heater, we will set out the repair cost next to a replacement option. Our installation page explains what replacement involves.
Should you switch the power off overnight?
There is no need to switch the heater off at the power point overnight just because of a lockout. Simply leave it at the controller until a technician can check it. Switching power on and off repeatedly does not help and can reset the controller clock.
Can a cold snap make lockouts more likely?
Yes. During long cold spells, heaters run more often and for longer. Any weakness in the igniter, sensor or gas supply shows up sooner. LPG pressure also drops in cold weather. If lockouts start during a cold snap, the cause may have been building for some time, and a service will usually reveal it.
What happens during a technician visit?
First, the technician confirms the gas supply and measures pressure at the heater. Next, they reset the heater and watch each ignition attempt. Then they inspect and clean the burners, test the igniter and flame sensor, check the gas valve and look at the flue and pressure switch. Finally, they explain the cause and quote before any repair.
Our repair page describes our general approach.
How quickly can a lockout be fixed?
We fix many lockouts on the first visit. Cleaning burners and the flame sensor, or replacing an igniter, often takes little time. A gas valve or control board may need ordering, in which case we explain the timeline and return once the part arrives.
Can a service prevent lockouts?
Yes, in most cases. Brivis recommends servicing at least every two years. A service cleans burners, checks ignition parts, confirms gas pressure and tests safety devices. Our service page lists everything a visit covers.
How do you book?
Call 02 9071 1142 and tell us you have code 50, whether other gas appliances work and what you have tried. You can also use our contact page and we will call you back to arrange a time.
Frequently asked questions
What does Brivis code 50 mean?
The heater locked out after four failed ignition attempts.
How do I reset code 50?
Press Reset, usually Key 4. If not shown, press FN, Key 1, then Key 4.
Why does code 50 come back?
The cause of the failed ignitions has not been fixed.
What should I check first?
Gas on at the meter and heater tap, other gas appliances and LPG cylinder levels.
Is code 50 dangerous?
The lockout is a safety feature. If you smell gas, turn it off at the meter and call for help.
How do I book a technician?
Call 02 9071 1142 or use our contact page.