Brivis ICE Cooling Not Working, Causes and Checks
Brivis ICE cooling not working on a hot day turns a convenient DualComfort system into a source of frustration.
Because add on cooling shares the heater fan and ducts, problems can come from the cooling side, the heater side or the controls. This guide walks through the checks in order, from the controller symbols to the outdoor unit, and explains which faults need a licensed technician.
Why is Brivis ICE cooling not working?
Brivis ICE add on cooling has three main parts. An outdoor unit with a compressor, a coil fitted with the gas heater and the heater fan that pushes air across the coil and through the ducts. If any of these fails, or if the controls do not ask for cooling properly, the home stays warm. Common causes include the wrong mode, a compressor delay, a dirty filter, too few open outlets, an iced coil, an outdoor unit fault or a refrigerant leak.
Is cooling mode selected?
On the Networker, press the Mode key and select Cooling. In cooling mode, the temperature logic reverses, so the system cools the home down to the set temperature. Make sure the set temperature sits below the room temperature. If the controller is still in heating mode on a hot day, the system will do nothing.
What does the snowman show?
A solid snowman means the compressor is running. A flashing snowman means the compressor is in a delay period. That delay is normal and usually lasts a few minutes. If the snowman keeps flashing for a long time, or never appears, the system may not be calling for cooling or the outdoor unit may have a problem. Our cooling mode guide explains the symbols.
Is air coming from the outlets?
If no air comes from the outlets, the heater fan is not running. Check the controller and the heater power. A fan fault stops both heating and cooling. Our fan settings guide explains fan behaviour.
Is the filter clean?
The heater and cooling share one return air filter. A clogged filter cuts airflow across the cooling coil, which lowers cooling and can freeze the coil. Clean the filter every fortnight while you use cooling. Our filter guide shows how.
Are enough outlets open?
Cooling needs strong airflow. Closing many outlets or running only a small zone reduces airflow and can freeze the coil. Open more outlets and run a larger zone.
Is the outdoor unit running?
Look at the outdoor unit while the snowman shows solid. Its fan should spin and you should hear the compressor hum. If it is silent, check its circuit breaker or isolator. If it runs but the air inside stays warm, the system may be short of refrigerant or the coil may be iced.
Is the coil frozen?
Ice on the coil blocks airflow and stops cooling. Signs include weak airflow, water leaks as ice melts and frost on the pipes near the outdoor unit. Switch cooling off and run the fan only for a while to thaw the coil. Then clean the filter and open outlets. If icing returns, a technician should check the refrigerant charge and fan speed.
Could the system be low on refrigerant?
Refrigerant circulates in a sealed loop and does not get used up. If the system is low, it has a leak. Signs include weak cooling with the outdoor unit running, icing and longer run times. A licensed technician must find and repair the leak, then recharge. Our gas and regas page explains the process.
Is water leaking?
Cooling removes moisture, which drains away from the coil. A blocked drain can overflow and stain ceilings below roof heaters. Turn cooling off and call us. Our water leaks guide explains more.
Why does cooling work in the morning but fade in the afternoon?
On a hot afternoon, the outdoor unit works hardest, the roof space around the heater coil and ducts is at its hottest and the home has absorbed heat all day. A system that is marginal, for example slightly low on refrigerant or with a dirty outdoor coil, may cope in the morning and fall behind later. Ducts running through a hot roof also gain heat before cool air reaches the rooms. Start cooling early, close blinds and keep the outdoor unit clear. If the fade is severe, a technician should check the charge and the outdoor coil.
Can a dirty outdoor coil reduce cooling?
Yes. The outdoor unit rejects heat through its coil. Leaves, dust, cobwebs and grass clippings clog the fins and reduce airflow, so the system struggles to shed heat. With the power off at the isolator, you can gently remove loose leaves from around the unit. A technician cleans the coil properly during a service.
Can the outdoor unit overheat?
On very hot days, especially when the outdoor unit sits in full sun or a cramped corner, it may overheat and stop to protect itself. Cooling then pauses until it cools down. Shade without blocking airflow, clear space around the unit and a clean coil all help.
Why does the heater fan run but no cool air comes?
If the heater fan runs and the snowman shows solid, yet the air stays warm, the outdoor unit may not be running, the refrigerant may be low or the coil may be iced. A flashing snowman means the compressor is waiting. When no snowman appears at all, the controller may not be calling for cooling. Note what the controller shows when you call.
Can a gas heater fault stop cooling?
The cooling side uses the heater fan, so a fan fault, a heater board fault or a power problem at the heater can stop cooling too. Gas faults, such as ignition problems, usually do not affect cooling, because the burners do not run in cooling mode.
When should cooling be serviced?
A check before summer suits most homes. It covers the outdoor unit, the coil, the condensate drain, the refrigerant circuit and the shared fan and filter. Combining it with regular heater servicing keeps the whole DualComfort system in shape.
Is add on cooling covered by warranty?
If a part fails in a young system, warranty may apply. Refrigerant leaks from installation joints, damage from debris or lack of maintenance may not be covered. Brivis does not warrant ductwork or installation. Keep your purchase details handy and ask us about your situation.
How do you check the outdoor unit safely?
Stand beside the outdoor unit while cooling is selected and the snowman shows solid. Listen for the fan and a steady hum from the compressor, and feel for warm air blowing out of the unit. Look for leaves, stored items or plants crowding it. Do not remove panels or touch wiring. If the unit is silent, check its isolator switch and the circuit breaker at the switchboard. If a breaker has tripped, reset it once, and if it trips again, leave it off and call us.
What does frost on the pipes mean?
Frost or ice on the copper pipes near the outdoor unit or the heater coil suggests the coil is running too cold. That can come from low airflow, a dirty filter, too few open outlets or low refrigerant. Switch cooling off and run the fan only to thaw the ice. Then check the filter and outlets. If frost returns, book a technician.
Why does the system cool some rooms but not others?
If some rooms cool well and others stay warm, the problem is usually in the ducts, zones or outlets rather than the cooling system. Upstairs rooms, rooms with large west facing windows and rooms at the end of long duct runs often lag in summer. Our cold rooms guide covers duct and outlet issues that apply equally to cooling.
How long should the system take to cool the home?
On a very hot day, cooling a home that has absorbed heat all day can take a few hours. Starting earlier, before the heat builds, makes a big difference. If the system runs for many hours without reaching a moderate target, even on a mild day, a fault is more likely.
Why does the compressor start and stop often?
Frequent compressor starts can come from a thermostat in a poor position, a system that is oversized for the home, low refrigerant or an outdoor unit protecting itself from overheating. Each start adds wear. Note how often it happens and mention it when you call.
What should you tell us when you call?
Tell us the controller mode, whether the snowman is solid or flashing, whether the outdoor unit runs, how the air feels at the outlets and whether you see ice or water. Mention when the system was last serviced and the heater model, plus any recent storms, power cuts or work near the outdoor unit.
How does a refrigerant leak repair work?
When a technician suspects a leak, they first confirm the shortage by measuring pressures and temperatures. Next, they search for the leak using electronic detection, bubble solution or a nitrogen pressure test. Common leak points include flare joints at the outdoor unit and coil, service valves and corroded sections of coil. Once found, the leak is repaired, the system is pressure tested, then evacuated with a vacuum pump to remove air and moisture. Finally, the system is recharged with the correct refrigerant by weight. Our gas and regas page explains each step in more detail.
Simply topping up refrigerant without fixing the leak wastes money, because the gas escapes again.
Can a power surge stop cooling?
Yes. Storms and surges can damage the outdoor unit board, the heater board or the controller. After a storm, if cooling will not start, check the breakers first. If the outdoor unit or controller stays unresponsive, call us.
Is it safe to keep trying cooling?
With an icing coil or leaking water, stop using cooling until the cause is fixed. If the outdoor unit makes grinding, squealing or banging noises, switch it off. Otherwise, running cooling with weak performance does no immediate harm, but it wastes energy until the fault is fixed.
How do you stay cool meanwhile?
Close blinds and curtains on sunny windows, use ceiling or pedestal fans, keep doors shut to the hottest rooms and run the heater fan only in the evening to move cooler night air around once outside temperatures drop. Drink plenty of water on very hot days and check on elderly neighbours.
Can the controller position affect cooling?
Yes. If the controller sits in a cool spot, such as a shaded hallway, it may reach its cooling target while sunny rooms stay warm. If it sits in a hot spot, such as near a west facing window, it may run the system constantly. Moving the controller or adding a remote sensor can balance comfort. A technician can advise during a visit.
Does add on cooling need different fan settings?
Cooling usually needs more airflow across the coil than heating needs across the heat exchanger. The system manages this, but installers set fan speeds during commissioning. If cooling has always been weak, the fan setting may need adjusting for your ducts. A technician can check it.
What will a technician check?
A technician checks the controller and settings, the heater fan, the filter and outlets, the outdoor unit electrics and fan, the compressor, the coil, the condensate drain and the refrigerant pressures. They explain the cause and quote before any repair.
How do you book?
Call 02 9071 1142 or use our contact page. Summer is busy, so calling at the first sign of weak cooling usually gets you a quicker appointment.
Frequently asked questions
Why is my Brivis add on cooling not working?
Wrong mode, compressor delay, dirty filter, iced coil, outdoor unit fault or low refrigerant.
What does a flashing snowman mean?
The compressor is in a delay period. Wait a few minutes.
Why does the coil ice up?
Low airflow or low refrigerant can freeze the coil.
Does refrigerant need topping up regularly?
No. Low refrigerant means a leak that needs repair.
Why is water leaking in cooling mode?
The condensate drain may be blocked.