Brivis Networker Symbols and What They Mean

Brivis Networker symbols tell you what the heater, cooler or add on cooling is doing at any moment.

Many owners mistake normal symbols for faults, such as a flashing snowman or a flashing zone arrow. Others, such as a scrolling error message or a spanner, do ask for attention. This page explains the common symbols on the Networker and how they relate to error codes, resets and service reminders.

Why do Brivis Networker symbols matter?

The Networker is the main window into your Brivis system. It shows the mode, the set temperature, the zones, the program period and the current state of the heater or cooler. When something unusual happens, it also shows messages and error codes. Understanding the normal symbols helps you spot the unusual ones quickly, and it saves unnecessary service calls.

What does the flame symbol mean?

A flame symbol shows that the heater is in heating mode and the burners are being called on. On Classic models, the manual describes a solid flame and a rotating fan as the normal display while heating. If that display stays on for more than about eight minutes with no fan and no heat, the manual suggests turning the Networker off and on, and if that fails, turning the heater off and on.

What does the fan symbol mean?

A rotating fan shows the main fan is running. On StarPro models, pressing Key 1 runs the fan continuously without heat. Between heating cycles, StarPro heaters may also run the fan at a low constant speed, which an installer or technician can adjust. On Classic models, the fan runs at full speed whenever it runs, regardless of the dial setting.

What does the snowman symbol mean?

On systems with Brivis add on refrigerated cooling, selecting Cooling with the Mode key brings up a snowman symbol when the compressor is running. A flashing snowman means the compressor is in a delay period. That delay protects the compressor from starting too soon after stopping, so a flashing snowman is normal for a short time. Our cooling mode guide explains more.

In cooling mode the temperature logic reverses. The system cools the home down to the set temperature, rather than heating it up.

What do the zone arrows mean?

On zoned systems, each zone shows an arrow. A solid arrow means the zone is receiving heat. A flashing arrow means the zone has reached its temperature and closed. Zones A and B use Key 4, while zones C and D use Key 5. A flashing arrow is normal behaviour, not a fault.

Our zoning guide explains how zones open and close.

What does the spanner symbol mean?

A spanner symbol shows that the system has a message waiting. It may relate to a fault or to a service reminder. On many models, you can read the message through the system messages menu and then clear the spanner. If Reset appears beside Key 4, pressing it may clear the message. Otherwise, pressing FN then Key 1 can show the message, after which Key 4 resets.

If the spanner returns with the same message, book a service.

What does a scrolling message mean?

When the heater or cooler detects a fault, the Networker often scrolls a message across the top of the screen. It usually names the fault type, gives a code number and suggests calling for assistance. That number is the most useful detail. Our error code guide explains the common numbers.

What does the lock symbol mean?

The Networker can be locked with a four digit PIN, which stops children or visitors changing settings. Press FN then Key 2 to lock or unlock. The first time default PIN is 1111. After three wrong attempts, entry is aborted. If the screen shows a lock, the controller is locked, not faulty. Our Networker guide covers locking.

What do the program period names mean?

In automatic mode, the Networker runs a daily program with preset periods named Wake, Leave, Return, Presleep and Sleep. By default, Wake starts at six in the morning, Leave at nine, Return at four in the afternoon, Presleep at half past nine at night and Sleep at ten. Temporary changes revert at the end of the current period, while permanent changes go through the Prog key.

Seeing a period name is normal. Our auto program guide explains how to change the times and temperatures.

Why might the time and day be wrong?

If power to the system was off for two to three hours or more, the Networker may lose its time and day. The heater still restarts when power returns, yet the program may run at the wrong times until you reset the clock. Our power outage guide covers this.

What if the screen is blank?

A blank screen usually means no power to the controller or heater, a tripped breaker, a loose cable or a failed controller. Check the power point and breaker for the heater. If those are fine, our controller blank guide explains the next steps.

Do two Networkers show the same symbols?

Homes with two Networkers share settings between them. Only the master can set the clock and the program, and locking one locks both. Both screens should show the same mode and zone information. If one screen differs or shows a communication message, the link between them may need checking.

What does the set temperature display show?

The large number on the Networker is usually the set temperature, the target you want the home to reach. Some screens can also show the actual room temperature. If the room never reaches the set temperature, the heater may be undersized for the conditions, outlets may be closed or a fault may be limiting output. A difference of a degree or two on very cold nights is common, while a large gap deserves a check.

Why does the fan keep running after heating stops?

At the end of a heating cycle, the heater keeps the fan running for a short time to move the remaining warmth out of the heat exchanger. On StarPro models, a low constant fan may also run between cycles. Both are normal. The fan symbol can therefore stay on for a while after the flame symbol disappears.

What does it mean when nothing seems to happen at start up?

When you turn the heater on, the burners light and warm the heat exchanger for about a minute before the main fan starts. During that minute, the screen may show heating mode but no warm air reaches the rooms yet. That short delay prevents cold draughts and is normal.

What about the Touch controller?

Newer installations may use the Brivis Touch controller instead of the Networker. The Touch controller shows similar information on a touch screen, including modes, zones and fault messages. Symbols may look a little different, yet the meanings are similar. With a wifi module and a compatible controller, the Rinnai Touch app can also show the system status on your phone.

Can a symbol stick on the screen?

Occasionally, a display can freeze or a symbol can stay on after its condition has passed, especially after a power flicker. Turning the Networker off for two minutes and back on often refreshes it. If the screen stays frozen, cut power to the heater for about a minute. If problems continue, the controller may need checking.

Do evaporative coolers use different symbols?

When a Networker controls an evaporative cooler, the screen shows cooler modes, fan speeds and pump status instead of heating symbols. The Contour manual notes the cooler may delay starting while it opens its seal, fills and pre wets the pads, and the Networker can show a time delay during that phase. A cooler fault appears as a scrolling message with a code. Our cooler fault page explains those messages.

Why do owners mistake normal symbols for faults?

Flashing symbols look like warnings, so it is natural to worry about them. On a Brivis Networker, though, flashing often means waiting or satisfied, such as a compressor delay or a zone at temperature. Error codes, by contrast, usually come with a scrolling message and a number. If you see a number, it is worth acting on. If you only see a flashing snowman or arrow, give the system time.

Can children change settings by accident?

Yes, which is why the PIN lock exists. Small hands can change modes, turn off zones or alter the program. If settings keep changing unexpectedly, lock the Networker with a PIN and share it only with the adults who need it. That simple step also stops guests from turning the heat up high and leaving it running.

What do the up and down keys change?

The up and down keys adjust the set temperature for the current mode and period. In automatic mode, a change made this way is temporary and reverts at the end of the current program period. To make the change stick, use the Prog key to edit the program itself. Many owners think the heater is ignoring them when their temporary change disappears at the next period, but that is the program working as designed.

How do the keys and FN work together?

The Networker has numbered keys whose roles change depending on the screen. The FN key unlocks secondary functions. For example, FN then Key 1 can show a waiting message, and FN then Key 2 locks or unlocks the controller. Key 4 often acts as Reset when a fault is present. Learning these few combinations covers most everyday needs. Our Networker guide lists them in one place.

What if the screen shows Cooling but the system blows warm air?

If cooling mode is selected but the snowman flashes, the compressor is waiting out its delay. Give it a few minutes. If the snowman shows solid and the air stays warm for a long time, the add on cooling may have a fault, such as a refrigerant problem or an outdoor unit issue. Our add on cooling problems page explains what to check.

Should you photograph the screen when calling?

Yes. A photo of the screen captures the mode, the set temperature, the zones and any message exactly as it appeared. It removes any guesswork and helps us prepare. Many owners find it easier than describing symbols over the phone.

How long should you wait before worrying?

As a guide, allow about a minute after start up for the burners to warm before the fan runs, a few minutes for a flashing snowman to turn solid and a reasonable time for zones to reach temperature on cold nights. If the screen shows a scrolling message with a number, or the same state persists far longer than usual with no warm or cool air, that is the time to act. Note what you see, try the reset steps if a fault number appears and then call us if it persists.

Patience with normal symbols, combined with prompt action on real messages, keeps your system safe and avoids unnecessary call outs.

How do we use the symbols during diagnosis?

When we arrive, we look at the controller first. The mode, the zone arrows, the snowman and any message tell us what the system was trying to do when the problem happened. That saves time and points us to the right part of the system.

How do you book help?

If a symbol or message has you puzzled, call 02 9071 1142 and describe what you see. A photo of the screen is ideal. You can also use our contact page.

Frequently asked questions

What does a flashing snowman mean on a Brivis Networker?

The add on cooling compressor is in a delay period. It is normal for a short time.

What does a flashing zone arrow mean?

The zone has reached its temperature and closed.

What does the spanner symbol mean?

A message is waiting, either a fault or a service reminder.

What is the default Networker PIN?

The first time default is 1111.

Why is the time wrong after a power cut?

The Networker may lose its clock if power was off for two to three hours or more.

How do I book help?

Call 02 9071 1142 or use our contact page.

{“@context”:”https://schema.org”,”@type”:”HVACBusiness”,”@id”:”https://brivis.sydneyaircare.com.au/#business”,”name”:”Sydney Air Care, Brivis Service”,”url”:”https://brivis.sydneyaircare.com.au/”,”description”:”Brivis ducted heating and cooling repair, service and troubleshooting across Sydney. Independent service provider, not affiliated with Brivis.”,”areaServed”:[{“@type”:”City”,”name”:”Sydney”},{“@type”:”State”,”name”:”New South Wales”}],”parentOrganization”:{“@type”:”Organization”,”name”:”Sydney Air Care”,”url”:”https://sydneyaircare.com.au/”},”telephone”:”+61 2 9071 1142″} {“@context”:”https://schema.org”,”@type”:”FAQPage”,”mainEntity”:[{“@type”:”Question”,”name”:”What does a flashing snowman mean on a Brivis Networker?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The add on cooling compressor is in a delay period. It is normal for a short time.”}},{“@type”:”Question”,”name”:”What does a flashing zone arrow mean?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The zone has reached its temperature and closed.”}},{“@type”:”Question”,”name”:”What does the spanner symbol mean?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”A message is waiting, either a fault or a service reminder.”}},{“@type”:”Question”,”name”:”What is the default Networker PIN?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The first time default is 1111.”}},{“@type”:”Question”,”name”:”Why is the time wrong after a power cut?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The Networker may lose its clock if power was off for two to three hours or more.”}},{“@type”:”Question”,”name”:”How do I book help?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Call 02 9071 1142 or use our contact page.”}}]}