Brivis Networker Instructions in Plain English

These Brivis Networker instructions cover the everyday tasks owners ask about most.

The Networker controls Brivis ducted gas heaters, add on cooling and evaporative coolers, and it shows error codes when something goes wrong. Its numbered keys change roles depending on the screen, which can confuse new owners. This guide explains the main keys and modes so you can run the system with confidence.

What does the Networker control?

The Networker is the wall controller used with many Brivis systems. It sets the mode, the temperature, the fan, the zones and the daily program. It also reports faults, shows service messages and supports a PIN lock. Some homes have the newer Brivis Touch controller instead, which offers similar functions on a touch screen.

How do you turn the heater on and off?

Use the on and off key. After you switch on, give the system a minute or so. The burners need that time to warm the heat exchanger, and only then does the main fan push warm air to the rooms. After switching off, you may hear the fan carry on briefly while it clears leftover warmth from the heater.

How do you change the temperature?

Raise or lower the target with the arrow keys. In manual operation, your new figure holds until you alter it again. In program operation, though, an arrow key adjustment only lasts until the next period begins. For a change you want every day, open the program with the Prog key and edit that period instead.

What are the main modes?

Most Networkers offer manual heating, program heating and, on suitable systems, cooling. Homes with refrigerated add on cooling pick it through the Mode key, while homes with a Brivis evaporative cooler see cooler options instead. Each mode has its own screen layout, so the numbered keys may do different things in each one.

How does the automatic program work?

Program operation splits the day into five named blocks, each with its own start time and target temperature. Out of the box, the first block begins early in the morning and the last begins mid evening. You can shift those times and temperatures to suit work hours, school runs and bedtimes. Our auto program guide walks through editing them.

How do you set the time and day?

Programs depend on the clock, so an accurate time and day matter. Use the clock function on the main controller to set them. Long outages can wipe the clock, so check it whenever the power has been off for a few hours. Our power outage guide covers what else to check after an outage.

How do you run the fan without heat?

StarPro owners can circulate air without lighting the burners by choosing continuous fan, usually on Key 1. That helps spread warmth from a sunny room to shaded ones. Fan behaviour differs between ranges, and some settings are reserved for installers. Our fan settings guide explains those differences.

How do zones work on the Networker?

Zoned homes can switch groups of rooms on and off from the controller, with two zones sharing each zone key. Small arrows beside each zone tell you whether it is calling for heat or resting. Our zoning guide explains how to pick zones without starving the heater of airflow.

How do you lock the Networker?

A PIN stops curious children or guests changing your settings. Locking and unlocking both go through the function key combined with a numbered key, and a factory PIN applies until you choose your own. The manual lists the exact keys, and the factory code is 1111.

How do two Networkers work together?

Larger homes sometimes have a second controller upstairs or in a bedroom wing. The pair shares one set of settings, with one acting as the main unit. Clock and program edits belong on the main unit. If the two ever disagree, start any checks there.

How do you reset after a fault?

Fault resets use the reset label that appears on screen when a fault is present. If the label is missing, a short key sequence brings it up. Should that not work, a longer pause with the controller off, followed by a brief power cut to the heater, is the next step. Our reset guide lists the full sequence in order.

How do you read waiting messages?

A small spanner icon tells you a message is stored. The function key sequence shown in the manual displays it, and once read you can usually clear it. Repeat messages are a sign to book a visit. Our Networker symbols page describes the icons you may see.

What if the Networker does not respond?

A dead screen or unresponsive keys usually start with power. Confirm the heater circuit is on and try a short power cycle at the heater supply. Should the controller stay dark, the fault may lie in the controller itself or its cable. Our controller blank guide goes through the likely causes.

Can you control the system from a phone?

With a compatible controller and a wifi module, owners can use the Rinnai Touch app. Older Networkers may not support app control. If you would like app control, ask us whether your system can be upgraded.

How do Brivis Networker instructions apply to controller placement?

The Networker measures the room temperature where it hangs, so its position affects comfort. Ideally it sits on an internal wall in a main living area, away from direct sun, outlets, kitchens, doors and draughty hallways. A controller near a supply outlet or in afternoon sun can read too warm and switch the heater off early, leaving other rooms cold.

If your home always feels cooler than the screen suggests, the controller position may be the cause. A technician can advise on moving it or adding a remote temperature sensor.

What temperature should you set?

Comfort is personal, yet many households find somewhere around twenty degrees comfortable in winter living areas, with a little less in bedrooms overnight. Every degree higher adds to running costs. Using the program to lower the temperature when the home is empty or everyone is asleep saves gas without sacrificing comfort.

How does the Networker work with an evaporative cooler?

When a Brivis evaporative cooler is connected, the Networker offers cooling modes, fan speeds and the option to run the fan with or without the pump. Running the fan without the pump moves air without adding moisture, which helps on humid days. Expect a short pause before the fan starts, since the cooler first opens, fills its tank and soaks its pads.

Our evaporative cooling page covers coolers in more detail.

How does the Networker work with add on cooling?

Brivis ICE add on cooling turns the heater ducts into a summer cooling system. Choose cooling through the Mode key and set the target you want the rooms to drop to. A small cold weather icon tells you the outdoor unit is working, and when it blinks, the system is simply waiting before it starts. Our cooling mode guide covers this in depth.

Why do the numbered keys change meaning?

The Networker uses a small set of keys for many functions. The label beside each key on the screen tells you what it does at that moment. For example, the same key can switch a pair of zones on one screen and clear a fault on another. Reading the on screen labels before pressing a key avoids most confusion.

What should you do if settings keep changing?

Unexpected changes usually have a simple explanation. Someone in the home may be pressing keys, or the program may be moving into a new period. Review the program times first. When changes still seem random, set a PIN, and in homes with two controllers, check both.

Is it worth keeping the manual?

Yes. The owner manual includes the outlet charts, the error code list, the reset steps and the program instructions for your model. If you have lost it, the model number on the heater data plate helps you find the right one. Keep it with your service records.

Can a technician change advanced settings?

Some settings, such as the low constant fan speed between heating cycles and certain installer parameters, are only adjustable by an installer or technician. If you think a setting needs changing, such as the fan speed for a particular duct system, mention it during a service.

How can you save gas with the controller?

The controller is your main tool for cutting gas use. Set a modest target in living areas, lower it overnight and drop it further when the home is empty. Use zones to heat only the rooms in use, as long as enough outlets stay open for the heater to breathe. Finally, check the program after daylight saving changes and school holidays, since routines shift and the heater may be warming an empty home.

Small changes add up. Lowering the target by one or two degrees across a whole winter makes a noticeable difference to the gas bill.

What does the controller do during a fault?

When the heater or cooler detects a problem, the controller displays a message, usually with a number, and may suggest calling for assistance. Some faults stop the system entirely, while others allow it to continue in a limited way. Either way, the number is the key detail. Write it down or take a photo, then follow the steps in our error code guide.

How do you care for the controller itself?

Wipe the screen gently with a soft, dry cloth. Avoid spraying cleaners directly onto it, as liquid can seep behind the buttons. Keep it out of direct sun if you can, since heat and sunlight can fade the display over many years. If buttons become unresponsive or the screen dims badly, the controller may be ageing and could need replacing.

Can older controllers be upgraded?

In many cases, yes. Newer controllers such as the Brivis Touch can replace older ones on compatible heaters, adding a clearer display and, with a wifi module, app control. Compatibility depends on the heater model and age. A technician can check your heater data plate and existing wiring before recommending an upgrade.

Why might the controller show a different temperature from a thermometer?

The controller reads the temperature at its own position, which may differ from the middle of a room or a bedroom down the hall. Sun, outlets and draughts near the controller all skew the reading. A difference of a degree or so is common. If the gap is large, consider moving the controller or adding a remote sensor.

What should visitors and tenants know?

If guests, house sitters or tenants will use the system, show them the on and off key, the arrow keys and how to tell when the heater is running. Explain that program changes are temporary, so they do not think the heater is ignoring them. Leave a short note near the controller with these basics and the number to call if a fault message appears. A few minutes of explanation prevents most confused phone calls and accidental lockouts.

How do you know the controller is working properly?

A healthy controller responds instantly to key presses, shows a clear display and changes the heater behaviour within a minute or two. If keys lag, the display flickers or the heater ignores commands, the controller or its connection may need checking.

How do you book help?

If the Networker still has you puzzled, call 02 9071 1142 or use our contact page. A photo of the screen helps us answer quickly and accurately.

Frequently asked questions

How do I make a temperature change permanent?

Edit the program using the Prog key. Up and down changes in auto mode are temporary.

How do I run the fan only?

On StarPro models, press Key 1 for continuous fan.

What is the default PIN?

The first time default PIN is 1111.

Which Networker sets the clock?

Only the master Networker can set the clock and program.

What does a flashing zone arrow mean?

The zone has reached its temperature and closed.

Can I use an app?

With a compatible controller and wifi module, the Rinnai Touch app is available.

{“@context”:”https://schema.org”,”@type”:”HVACBusiness”,”@id”:”https://brivis.sydneyaircare.com.au/#business”,”name”:”Sydney Air Care, Brivis Service”,”url”:”https://brivis.sydneyaircare.com.au/”,”description”:”Brivis ducted heating and cooling repair, service and troubleshooting across Sydney. Independent service provider, not affiliated with Brivis.”,”areaServed”:[{“@type”:”City”,”name”:”Sydney”},{“@type”:”State”,”name”:”New South Wales”}],”parentOrganization”:{“@type”:”Organization”,”name”:”Sydney Air Care”,”url”:”https://sydneyaircare.com.au/”},”telephone”:”+61 2 9071 1142″} {“@context”:”https://schema.org”,”@type”:”FAQPage”,”mainEntity”:[{“@type”:”Question”,”name”:”How do I make a temperature change permanent?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Edit the program using the Prog key. Up and down changes in auto mode are temporary.”}},{“@type”:”Question”,”name”:”How do I run the fan only?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”On StarPro models, press Key 1 for continuous fan.”}},{“@type”:”Question”,”name”:”What is the default PIN?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The first time default PIN is 1111.”}},{“@type”:”Question”,”name”:”Which Networker sets the clock?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”Only the master Networker can set the clock and program.”}},{“@type”:”Question”,”name”:”What does a flashing zone arrow mean?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”The zone has reached its temperature and closed.”}},{“@type”:”Question”,”name”:”Can I use an app?”,”acceptedAnswer”:{“@type”:”Answer”,”text”:”With a compatible controller and wifi module, the Rinnai Touch app is available.”}}]}